APC Galaxy VX Double-conversion (Online) 500 kVA 500000 W
500.0kVA, 400V, 50 Hz +/- 0.1 %
APC Galaxy VX
Out of stock
Custom Spanstor Build & Test
As part of our Spanstor Build & Test services, any enclosure bought with drives, we will include all firmware installations, physical drive installations, RAID/cache configurations and drive bad-sector checks, all at no additional cost. If you have any questions, please contact our friendly sales team by chat, phone or email.
Parallel-redundant capable
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Parallel-capacity capable
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Internal backfeed protection
Increases system defense from power anomalies.
Energy storage flexibility
Conventional flooded and modular battery offer along with different charging modes allows tailoring to specific back-up requirements.
Compatible with Schneider Electric’s lithium ion battery solution
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability.
Total cost of Ownership
Robust operation
No power derating in kW up to 40 degrees C or 104 degrees F.
Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Serviceability
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
Multiple levels of service
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.
StruxureOn enabled
Simplify maintenance and operation of your equipment through the use of vendor-neutral, cloud-based software and services.
5×8 Start-up service included
Required for full coverage of factory warranty
Power | |
---|---|
Output voltage regulation | 0.3% |
Output power | 500000 W |
Input operation voltage (min) | 380 V |
Input operation voltage (max) | 440 V |
Output operation voltage (min) | 380 V |
Output operation voltage (max) | 440 V |
Maximum current | 851 A |
Power factor | 0.99 |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 3% |
Crest factor | 3:1 |
Output power capacity | 500 kVA |
ECO mode | Yes |
Performance | |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Number of output phases | 3 |
Number of input phases | 3 |
Power protection features | Overload |
Noise level | 69.5 dB |
Audible alarm(s) | Yes |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Double-conversion (Online) |
Waveform | Sine |
Output voltage regulation | 0.3% |
Number of output phases | 3 |
Number of input phases | 3 |
Output power | 500000 W |
Input operation voltage (min) | 380 V |
Input operation voltage (max) | 440 V |
Output operation voltage (min) | 380 V |
Output operation voltage (max) | 440 V |
Maximum current | 851 A |
Power protection features | Overload |
Power factor | 0.99 |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 69.5 dB |
Input current Total Harmonic Distortion (THD) | 3% |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 500 kVA |
ECO mode | Yes |
Input frequency | 40/70 Hz |
Compatibility | Schneider Electric’s lithium ion battery solution |
Ports & interfaces | |
SmartSlot | Yes |
AC outlet types | Hard Wire 4-wire (3PH + N) |
Design | |
International Protection (IP) code | IP20 |
Form factor | Large tower |
Compatibility | Schneider Electric’s lithium ion battery solution |
Product colour | White |
Certification | C-Tick, CE, CUL listed, IBC 2012, IEC 62040-1-1, IEC 62040-2, IEC 62040-3, IEC 62040-4, ISTA 2B, UL 1778 5th |
Operational conditions | |
Operating temperature (T-T) | 0 – 40 °C |
Storage temperature (T-T) | -15 – 40 °C |
Operating relative humidity (H-H) | 0 – 95% |
Operating altitude | 0 – 1015.9 m |
Non-operating altitude | 0 – 15240 m |
Technical details | |
Output frequency | 50/60 Hz |
Sustainability certificates | RoHS |
Weight & dimensions | |
Weight | 1880 kg |
Width | 2700 mm |
Height | 1970 mm |
Depth | 900 mm |
Package width | 3170 mm |
Package depth | 1060 mm |
Package height | 2150 mm |
Package weight | 2592 kg |
Packaging data | |
Package width | 3170 mm |
Package depth | 1060 mm |
Package height | 2150 mm |
Package weight | 2592 kg |
Certificates | |
Certification | C-Tick, CE, CUL listed, IBC 2012, IEC 62040-1-1, IEC 62040-2, IEC 62040-3, IEC 62040-4, ISTA 2B, UL 1778 5th |
Got a question?
If you have any questions, concerns or would simply like to know more about the products we sell, please don’t hesitate to contact us by using the options below.